(Model: MM-100 - With one mouse chamber, air pump, software, and all required accessories)
Oxygen consumption system for 1 - 16 animals

- More information - - Documents - - Contact Bioseb -
Technical specifications
Other products / accessory  
Download PDF
(Modif.) This page is available in following languages:

Presentation

The MM-100 Metabolic Monitor is a complete system for measuring oxygen consumption in the small animal. Using the latest technology in paramagnetic O2, infrared CO2, and thermal mass flowmeter analyzers, it automatically computes O2 consumption, CO2 production, and respiratory exchange ratios (RER).


Operating principle

The animal is placed in the provided chamber and allowed to equilibrate for 5 - 10 minutes.
All gas and flow measurements, and computed results are shown on the front panel LCD display panel. A serial port connection sends the measurements to any attached computer.
Using the included WindowsTM software, the readings for O2 consumption and CO2 production, along with their moving time averages, are plotted. Data can be logged to simple ASCII files for further analysis. Standardization against room air is automatically performed at intervals, so the accuracy of the system is maintained for long intervals of monitoring.


Multiple chamber systems

Expansion to multiple animals is straightforward. Using the MMX-4 or MMX-16 (for four and sixteen animals, respectively) expansion units, gas sampling and measurement is automatically sequenced between the chambers. This results in an accurate, economical system for screening large numbers of animals for these important physiological parameters.


Front panel display panel shows all gas, flow, and computed measurements, as well as elapsed time and chamber being monitored
Front panel display panel shows all gas, flow, and computed measurements, as well as elapsed time and chamber being monitored
MM-COMM Monitoring Software

Each MM-100 system includes WindowsTM software for graphically displaying and logging the metabolic data. This software provides a Data Panel showing all the current raw and computed measurements. Data is logged in a simple ASCII format for directly importing it into a spreadsheet or other analysis program. Each record is tagged with the animal number and time of the measurement.


Complete package

The MM-100 comes complete with all necessary components for a single-chamber measurement. This includes the main MM-100 unit, small animal chamber, air pump, drying tubes, and required tubing. The only consumable item is the Drierite material for drying the gas sample.

Screen example
Screen example
THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Oxygen analyzer type Paramagnetic
Linearity (0 - 100%) +0.1% O2
Repeatability < 0.01% O2/hour
Zero stability +0.002% O2/hour
Response time 2.0 seconds
Operating temperature 0 - 65oC
Maximum pressure 15 psi
Maximum sample flow 250 ml/min
Instrument measurement range 0 - 24.5%O2
Carbon Dioxide analyzer type Single-beam infrared
Operating range 0 - 5000ppm (0.5%) CO2
Linearity (full scale) 1% FS
Zero drift 2% FS/week
Sensor cell temperature Controlled at 60oC
Warm-up time <15 min
Maximum sample flow 200 ml/min
Instrument measurement range 0 - 0.41%CO2
Flow transducer Thermal mass flowmeter
Flow range 0 - 10,000 ml/min
Linear flow range 50 - 10,000 ml/min
Response time < 2S
Operating temperature -20 - 70oC
Main unit analog outputs Flow, O2, CO2
Analog signal outputs (rear panel) BNC jacks
Flow output 1mV/ml/min
Flow output zero offset 1.250V
O2 output 0.1667V/%O2
CO2 output 10V/%CO2
Serial data output format 9600 baud, 8 data bits, no parity, 1 stop bit
Serial data interval Complete set of readings sent 1 per minute
Serial output connector (rear panel) DB9 female
Dimensions, main unit 19W x 5.25H x 15D in.
Power requirements 120/240V (switchable), 200VA

Model:
MM-100
Metabolic Monitor System (Modif.)
With one mouse chamber, air pump, software, and all required accessories Contact us

Accessories :
PUMP-8
External Air Pump, 0-8l/min range, specify 110 or 220V (Modif.)
Contact us
PUMP-16
External Air Pump, 0-16l/min range, specify 110 or 220V (Modif.)
Contact us
Nafion-24
Sample line, 2 feet, Nafion® (evaporates condensed moisture), Luer M-F (Modif.)
Contact us
MMX-2
Two-chamber expansion unit with 2 chambers, connecting cable, and all (Modif.)
Contact us
MMX-8
Eight-chamber expansion unit with 8 mouse chambers, connecting cable, (Modif.)
Contact us
MMX-16
Sixteen-chamber expansion unit with 16 mouse chambers, connecting cabl (Modif.)
Contact us
MouseCage
Measurement chamber, approximately 1.5 liter volume, reusable (Modif.)
Contact us
RatCage
Measurement chamber, acrylic, approximately 6 liter volume, reusable (Modif.)
Contact us
DryingTube
Spare Drierite tube, pack of 4 (Modif.)
Contact us
PUMP-50
External Air Pump, 0-50l/min range (Modif.)
Contact us
CalGasMM-100
Calibration gas cylinder, 35 liter, 0.25% CO2, balance N2, with regula (Modif.)
Contact us
CalGascylinder
Calibration gas cylinder, 35 liter, 0.25% CO2, balance N2, without reg (Modif.)
Contact us
Print version

Bioseb - In Vivo Research Instruments
Phone worldwide : +33 442 344 360 - USA/Canada : (727) 521-1808
e-Mail : Worldwide: info@bioseb.com - USA/Canada: sales@eb-instruments.com