The pain_depression dyad is becoming widespread in the clinic and is attracting increasing attention. A previous study by our group found that...
Array
(
[id_prestablog_news] => 1144
[id_shop] => 1
[date] => 2017-05-19 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 2248
[id_lang] => 2
[title] => 5_HT in the dorsal raphe nucleus is involved in the effects of 100_Hz electro_ac
[paragraph] => 5_HT in the dorsal raphe nucleus is involved in the effects of 100_Hz electro_acupuncture on the pain_depression dyad in rats
[content] => Authors
Y_Y WU, Y_L JIANG, X_F HE, X_Y ZHAO, X_M SHAO, J SUN, Z SHEN, S_Y SHOU, J_J WEI, J_Y YE, S_S YAN, J-Q FANG
Lab
Department of Neurobiology and Acupuncture Research, The Third Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
Journal
Experimental and Therapeutic Medicine
Abstract
The pain_depression dyad is becoming widespread in the clinic and is attracting increasing attention. A previous study by our group found that 100_Hz ectro_acupuncture (EA), but not 2_, 50_ and 2/100_Hz EA, was effective against the reserpine_induced pain_depression dyad. This finding is in contrast to the fact that low_frequency EA is commonly used to treat supraspinal_originating diseases. The present study aimed to investigate the mechanism underlying the effects of 100_Hz EA on the pain_depression dyad. Repeated reserpine injection was found to induce allodynia and depressive behaviors in rats. It decreased _hydroxytryptamine (5_HT) levels and immunoreactive expressions in the dorsal raphe nucleus (DRN). 100_Hz EA alleviated the pain_depression dyad and upregulated 5_HT in the DRN of reserpine_injected rats. Intracerebroventricular injection of para_chlorophenylalanine, an inhibitor of 5_HT resynthesis, suppressed the upregulation of 5_HT in the DRN by 100_Hz EA and partially counteracted the analgesic and anti_depressive effects of 100_Hz EA. The present study was the first to demonstrate that 5_HT in the DRN is involved in mediating the analgesic and anti_depressive effects of 100_Hz EA on the pain_depression dyad. This finding provided a scientific basis for high_frequency EA as a potential treatment for the pain_depression dyad.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
[meta_description] =>
[meta_keywords] => https://www.spandidos-publications.com/10.3892/etm.2017.4479
[meta_title] =>
[link_rewrite] => 5ht-in-the-dorsal-raphe-nucleus-is-involved-in-the-effects-of-100hz-electroacupuncture-on-the-paindepression-dyad-in-rats
[actif_langue] => 1
[read] => 979
[count_comments] => 0
[id] => 1144
[categories] => Array
(
[57] => Array
(
[id_prestablog_categorie] => 57
[title] => Dépression
[link_rewrite] => Depression
)
[10] => Array
(
[id_prestablog_categorie] => 10
[title] => Douleur
[link_rewrite] => Douleur
)
[30] => Array
(
[id_prestablog_categorie] => 30
[title] => Douleurs chroniques
[link_rewrite] => Douleurs-chroniques
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
[15] => Array
(
[id_prestablog_categorie] => 15
[title] => Troubles de l'humeur
[link_rewrite] => Troubles-de-l-humeur
)
)
[authors] =>
[paragraph_crop] => 5_HT in the dorsal raphe nucleus is involved in the effects of 100_Hz electro_acupuncture on [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] => Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus