Inflammation of the synovium and joint capsule is a main driver of pain in an osteoarthritic (OA) joint. Triamcinolone acetonide (TAA) is a...
Array
(
[id_prestablog_news] => 1110
[id_shop] => 1
[date] => 2019-03-07 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 2182
[id_lang] => 2
[title] => Intra-articular injection of triamcinolone acetonide releasing biomaterial micro
[paragraph] => Intra-articular injection of triamcinolone acetonide releasing biomaterial microspheres inhibits pain and inflammation in an acute arthritis model
[content] => Authors
I Rudnik-Jansen, N Woike, N Woikeb, A Tellege et al
Lab
Department of Orthopedics, University Medical Center Utrecht, Utrecht, the Netherlands; bDSM Biomedical B.V, Geleen, The Netherland
Journal
Drug Delivery
Abstract
Inflammation of the synovium and joint capsule is a main driver of pain in an osteoarthritic (OA) joint. Triamcinolone acetonide (TAA) is a classical corticosteroid that reduces synovitis and alleviates pain, albeit transiently. Biomaterial-based local TAA release may prolong the suppression of pain without the need for multiple injections. Polylactic-co-glycolic acid (PLGA) formulations of TAA prolong OA pain relief to a limited extent. A novel polyesteramide (PEA) microsphere platform allows for extended release in the OA joint for over 3_months. To evaluate their effect on pain and inflammation, TAA-loaded microspheres were intra-articularly delivered to the knee joint in a rat model of acute arthritis induced by intra-articular injection of streptococcal cell wall peptidoglycan-polysaccharide (PGPS) and subsequent flare-ups by intravenous PGPS injections. PEA-loaded microspheres were benchmarked with TAA-loaded PLGA microspheres and bolus TAA injection. TAA treatments were injected intra-articularly before the first induced flare-up. TAA-loaded PEA and PLGA microspheres reduced joint swelling and signs of pain-like behavior over the entire study period, as assessed by weight bearing and referred mechanical hypersensitivity, whereas bolus suspension was effective for a shorter time period. TAA-loaded PEA microspheres reduced lameness to a greater extent than TAA-loaded PLGA microspheres. In conclusion, a single intra-articular injection of TAA-loaded PEA microspheres reduced joint swelling and induced longer pain relief compared to bolus injection. Hence relief of inflammation and pain by PEA-based delivery of TAA may prove to be effective and durable.
BIOSEB Instruments Used
Dynamic Weight Bearing 2.0 (BIO-DWB-DUAL)
[meta_description] =>
[meta_keywords] => https://www.tandfonline.com/doi/full/10.1080/10717544.2019.1568625?scroll=top&needAccess=true
[meta_title] =>
[link_rewrite] => intra-articular-injection-of-triamcinolone-acetonide-releasing-biomaterial-microspheres-inhibits-pain-and-inflammation-in-an-acute-arthritis-model
[actif_langue] => 1
[read] => 1121
[count_comments] => 0
[id] => 1110
[categories] => Array
(
[70] => Array
(
[id_prestablog_categorie] => 70
[title] => Arthrite & Arthrose
[link_rewrite] => Arthrite-Arthrose
)
[21] => Array
(
[id_prestablog_categorie] => 21
[title] => Articulations
[link_rewrite] => Articulations
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Intra-articular injection of triamcinolone acetonide releasing biomaterial microspheres [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1216] => Array
(
[name] => Distribution Pondérale Dynamique 2.0
[description_short] => Un système permettant l'analyse de la posture des animaux par la répartition du poids sur chacune des 4 pattes. Le DWB est un test unique dans l'étude de nombreux modèles de douleurs, principalement non évoquée , neuropathique ou encore inflammatoire ainsi que pour les études sur l'osthéoarthrite et divers affections du SNC.
Le nouvelle version DWB2 intègre une nouvelle interface logiciel plus simple avec gestion des listes d'animaux ainsi que de nouveaux algorithmes d'analyse automatique de la posture.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-spontanee-deficit-de-posture/1216-dynamic-weight-bearing-20.html
)
[1877] => Array
(
[name] => Dynamic Weight Bearing 2.0 – Module Postural Additionnel
[description_short] => Étendez votre analyse grâce à des calculs posturaux et locomoteurs avancés
Le système de Distribution Pondérale Dynamique (DWB2) de BIOSEB s’enrichit avec l'ajout du Module Postural. Ce complément logiciel optionnel améliore l’analyse standard de la répartition du poids en intégrant des nouveaux calculs conçus pour l’étude de la posture, de la locomotion et de l’activité des animaux.
Développé en collaboration avec le laboratoire du Dr. Tighilet de l’Université Aix-Marseille - CNRS, le Module Postural améliore votre DWB2 en fournissant des paramètres précieux pour les recherches sur la douleur, les troubles vestibulaires et les maladies neurodégénératives.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-spontanee-deficit-de-posture/1877-dynamic-weight-bearing-20-module-postural-additionnel.html
)
)
)
1 En lire plus