One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication...
Array
(
[id_prestablog_news] => 1951
[id_shop] => 1
[date] => 2024-01-11 00:00:00
[date_modification] => 2024-05-10 10:08:15
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[ishero] => 0
[prim_key] => 3613
[id_lang] => 2
[title] => Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution
[paragraph] => Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation
[content] => Authors
Viana, D., Walston, S.T., Masvidal-Codina, E. et al.
Lab
Journal
Nature Nanotechnology
Abstract
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3–5 mC cm−2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Keywords/Topics
Fonctions cérébrales
[meta_description] =>
[meta_keywords] => https://www.nature.com/articles/s41565-023-01570-5#citeas
[meta_title] =>
[link_rewrite] => nanoporous-graphene-based-thin-film-microelectrodes-for-in-vivo-high-resolution-neural-recording-and-stimulation
[actif_langue] => 1
[read] => 460
[count_comments] => 0
[id] => 1951
[categories] => Array
(
[37] => Array
(
[id_prestablog_categorie] => 37
[title] => Fonctions cérébrales
[link_rewrite] => Fonctions-cerebrales
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] =>
Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus