Microglial cell plays a crucial role in the development and establishment of chronic neuropathic pain after spinal cord injuries. As neuropathic...
Array
(
[id_prestablog_news] => 527
[id_shop] => 1
[date] => 2013-10-02 00:00:00
[date_modification] => 2024-02-09 14:15:11
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[ishero] => 0
[prim_key] => 1030
[id_lang] => 2
[title] => Phagocytic microglial phenotype induced by glibenclamide improves functional rec
[paragraph] => Phagocytic microglial phenotype induced by glibenclamide improves functional recovery but worsens hyperalgesia after spinal cord injury in adult rats
[content] => Authors
E. Redondo-Castro1, J. Hernández, N. Mahy, X. Navarro
Lab
Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Bellaterra, Spain
Journal
European Journal of Neuroscience
Abstract
Microglial cell plays a crucial role in the development and establishment of chronic neuropathic pain after spinal cord injuries. As neuropathic pain is refractory to many treatments and some drugs only present partial efficacy, it is essential to study new targets and mechanisms to ameliorate pain signs. For this reason we have used glibenclamide (GB), a blocker of KATP channels that are over expressed in microglia under activation conditions. GB has already been used to trigger the early scavenger activity of microglia, so we administer it to promote a better removal of dead cells and myelin debris and support the microglia neuroprotective phenotype. Our results indicate that a single dose of GB (1 μg) injected after spinal cord injury is sufficient to promote long-lasting functional improvements in locomotion and coordination. Nevertheless, the Randall–Selitto test measurements indicate that these improvements are accompanied by enhanced mechanical hyperalgesia. In vitro results indicate that GB may influence microglial phagocytosis and therefore this action may be at the basis of the results obtained in vivo.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
Keywords/Topics
Douleurs neuropathiques; Douleurs chroniques; Douleur
[meta_description] =>
[meta_keywords] => http://onlinelibrary.wiley.com/doi/10.1111/ejn.12382/abstract;jsessionid=19E41AA4AEF1B03374A4E9ABA7986140.f01t03?deniedAccessCustomisedMessage=&userIsAuthenticated=false
[meta_title] =>
[link_rewrite] => phagocytic-microglial-phenotype-induced-by-glibenclamide-improves-functional-recovery-but-worsens-hyperalgesia-after-spinal-cord-injury-in-adult-rats
[actif_langue] => 1
[read] => 1033
[count_comments] => 0
[id] => 527
[categories] => Array
(
[10] => Array
(
[id_prestablog_categorie] => 10
[title] => Douleur
[link_rewrite] => Douleur
)
[30] => Array
(
[id_prestablog_categorie] => 30
[title] => Douleurs chroniques
[link_rewrite] => Douleurs-chroniques
)
[29] => Array
(
[id_prestablog_categorie] => 29
[title] => Douleurs neuropathiques
[link_rewrite] => Douleurs-neuropathiques
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Phagocytic microglial phenotype induced by glibenclamide improves functional recovery but [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] =>
Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus