For assessing the suitability of a given material for peripheral nerve implantation, acute and chronic tests to investigate tissue reaction, and...
Array
(
[id_prestablog_news] => 765
[id_shop] => 1
[date] => 2015-04-22 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[ishero] => 0
[prim_key] => 1496
[id_lang] => 2
[title] => Biocompatibility evaluation of parylene C and polyimide as substrates for periph
[paragraph] => Biocompatibility evaluation of parylene C and polyimide as substrates for peripheral nerve interfaces
[content] => Authors
del Valle, J., de la Oliva, N., Muller, M., Stieglitz, T. et al.
Lab
Dept. of Cell Biol., Physiol. & Immunology, Univ. Autonoma de Barcelona, Bellaterra, Spain
Journal
Neural Engineering (NER)
Abstract
For assessing the suitability of a given material for peripheral nerve implantation, acute and chronic tests to investigate tissue reaction, and evaluate the thickness of fibroblast layers that surround the material and the presence of inflammatory cells are mandatory. In this study we compared in vivo the biocompatibility of parylene C and polyimide, two materials intended for fabrication of neural electrodes. We have tested these two materials after implantation of thin devices in the peripheral nerve of rats, by functional and morphological methods, assessing thickness of the fibrotic capsule, signs of inflammation and axon survival in areas close to the implant. Intraneural implantation of parylene C and polyimide devices did not produce any functional alteration in the sciatic nerve, as evidenced by electrophysiological, locomotion and nociceptive functional tests. The intraneural devices were encapsulated within a fibroblastic tissue. Resolution of the inflammatory infiltrate took 4-8 weeks. In conclusion, both parylene and polyimide electrodes show biocompatible characteristics and induce a similar fibrotic reaction after chronic intraneural implantation.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
Keywords/Topics
Domaines de recherche divers
[meta_description] =>
[meta_keywords] => http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7146654&punumber%3D7131936%26filter%3DAND(p_IS_Number%3A7146535)%26pageNumber%3D5
[meta_title] =>
[link_rewrite] => biocompatibility-evaluation-of-parylene-c-and-polyimide-as-substrates-for-peripheral-nerve-interfaces
[actif_langue] => 1
[read] => 1140
[count_comments] => 0
[id] => 765
[categories] => Array
(
[26] => Array
(
[id_prestablog_categorie] => 26
[title] => Domaines de recherche divers
[link_rewrite] => Domaines-de-recherche-divers
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Biocompatibility evaluation of parylene C and polyimide as substrates for peripheral nerve [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] =>
Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus