Background Oro-facial pain is more prevalent in women than in men, and oestrogen may underlie this sex difference. Genistein reversed the...
Array
(
[id_prestablog_news] => 1422
[id_shop] => 1
[date] => 2021-06-02 00:00:00
[date_modification] => 2024-02-09 14:15:13
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[ishero] => 0
[prim_key] => 3039
[id_lang] => 2
[title] => Genistein reverses the effect of 17beta_estradiol on exacerbating experimental o
[paragraph] => Genistein reverses the effect of 17beta_estradiol on exacerbating experimental occlusal interference_induced chronic masseter hyperalgesia in ovariectomized rats
[content] => Authors
Y Liu, XY Zhang, YY Fan et al
Lab
Peking University School and Hospital of Stomatology, Beijing, China.
Journal
Journal of Oral Rehabilitation
Abstract
Background Oro-facial pain is more prevalent in women than in men, and oestrogen may underlie this sex difference. Genistein reversed the potentiation of 17beta-estradiol (E2) on glutamate-induced acute masseter nociceptive behaviour, but its role in dental experimental occlusal interference (EOI)-induced chronic masseter hyperalgesia remains unclear.
Objective This study aimed to investigate sex differences, and to explore the role and underlying mechanisms of genistein in E2-potentiated EOI-induced chronic masseter hyperalgesia in rats.
Methods Female and male rats were prepared to compare the sex differences of masseter hyperalgesia induced by EOI using a 0.4-mm-thick metal crown. Female rats were ovariectomised (OVX) and treated with E2 and genistein, followed by EOI. The head withdrawal threshold (HWT) was examined to assess masseter sensitivity. The protein expression of transient receptor potential vanilloid-1 (TRPV1) in the trigeminal ganglion (TG) was detected using western blotting. Immunofluorescence staining was used to reveal the colocalisation of oestrogen receptors (ERs) with TRPV1 and the percentage of TRPV1-positive neurons in the TG.
Results To some extent, female rats displayed enhanced sensitivity to EOI-induced chronic masseter hyperalgesia compared with males. Female rats showed the lowest HWT in the pro-oestrus phase. Pre-treatment with genistein antagonised E2 potentiation in EOI-induced masseter hyperalgesia and blocked the effect of E2 by downregulating TRPV1 protein expression and the percentage of TRPV1-positive neurons in the TG.
Conclusion Female rats showed greater masseter hyperalgesia than males under EOI. Genistein antagonised the facilitation of EOI-induced chronic masseter hyperalgesia by E2 probably through inhibiting TRPV1 in the TG.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
Keywords/Topics
Douleurs oro-faciales
[meta_description] =>
[meta_keywords] => https://doi.org/10.1111/joor.13213
[meta_title] =>
[link_rewrite] => genistein-reverses-the-effect-of-17betaestradiol-on-exacerbating-experimental-occlusal-interferenceinduced-chronic-masseter-hyperalgesia-in-ovariectomized-rats
[actif_langue] => 1
[read] => 951
[count_comments] => 0
[id] => 1422
[categories] => Array
(
[31] => Array
(
[id_prestablog_categorie] => 31
[title] => Douleurs oro-faciales
[link_rewrite] => Douleurs-oro-faciales
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Genistein reverses the effect of 17beta_estradiol on exacerbating experimental occlusal [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] =>
Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus