The transverse intrafascicular multichannel electrode (TIME) is intended to be transversally implanted in the peripheral nerve and to selectively...
Array
(
[id_prestablog_news] => 322
[id_shop] => 1
[date] => 2011-05-12 00:00:00
[date_modification] => 2024-02-09 14:15:11
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[ishero] => 0
[prim_key] => 640
[id_lang] => 2
[title] => Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichanne
[paragraph] => Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode (TIME) in the Rat Sciatic Nerve.
[content] => Authors
J. Badia, T. Boretius, A. Pascual-Font , E. Udina, T. Stieglitz et al.
Lab
Universitat Autònoma de Barcelona, Physiology and Immunology, Department of Cell Biology, Bellaterra, Spain.
Journal
IEEE Transactions on Biomedical Engineering
Abstract
The transverse intrafascicular multichannel electrode (TIME) is intended to be transversally implanted in the peripheral nerve and to selectively interface subsets of axons in different fascicles within the same nerve. Two versions of TIME (TIME-2, TIME-3) were designed and tested for biocompatibility and safety in the sciatic nerve of the rat. TIME-2 was implanted in two groups: one group had only an acute implant and the second group had chronic implantation for 2 months; a third group was also chronically implanted with the TIME-3 version, designed to avoid the mechanical traction produced by muscles motion. We evaluated the functional and morphological effects of either TIME-2 or TIME-3 implanted in the rat sciatic nerve for 2 months. The results of the study indicate that implantation of the TIME-2 and TIME-3 devices in the rat sciatic nerve did not cause significant axonal loss or demyelination, as evidenced by the functional and histological results. The results of this study indicate that the TIME-2 and TIME-3 designs are biocompatible and safe after chronic implantation in a small peripheral nerve, such as the rat sciatic nerve.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
Keywords/Topics
Domaines de recherche divers
[meta_description] =>
[meta_keywords] => http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5766019
[meta_title] =>
[link_rewrite] => biocompatibility-of-chronically-implanted-transverse-intrafascicular-multichannel-electrode--time--in-the-rat-sciatic-nerve--
[actif_langue] => 1
[read] => 1107
[count_comments] => 0
[id] => 322
[categories] => Array
(
[26] => Array
(
[id_prestablog_categorie] => 26
[title] => Domaines de recherche divers
[link_rewrite] => Domaines-de-recherche-divers
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Von Frey Électronique - Sans Fil
[description_short] =>
Une solution rapide pour déterminer le seuil de sensibilité à la douleur mécanique chez les rongeurs (rats et souris). Maintenant en version sans-fil, pour être libéré des câbles!
Cet instrument électronique précis et simple d'utilisation est le test de référence pour vos recherches en analgésie, nociception, neuropathies et douleurs post-opératoires


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Von Frey Électronique 5 avec caméra intégrée
[description_short] =>
En tant que version électronique du classique esthésiomètre à filaments de Von Frey, la dernière évolution de l’instrument électronique Von Frey de Bioseb, conçu pour déterminer le seuil de sensibilité mécanique chez les rongeurs (rats et souris) par stimulation sous la patte, est un outil indispensable pour vos recherches sur l’hyperalgésie et l’allodynie. En mesurant et en enregistrant la force à laquelle l’animal présente un réflexe de retrait de la patte, il est possible d’étudier les pathologies liées à la réponse sensorielle ainsi qu’à l’hyper- ou l’hypoesthésie.
L'EVF5 intègre une caméra embarquée au niveau de la zone de stimulation et fonctionne avec un nouveau logiciel dédié révolutionnaire


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 En lire plus