Publications

Dernière publication 01/01/2024

Up to the maximum-testosterone dose-dependent effects on anabolic and androgen r

The antigen retrieval for the prostate slides was carried out in 10mM Tris-EDTA (pH 9.0) at 60C over night. Then, the Millipore IHC SelectHRP/DAB...

Array
(
    [id_prestablog_news] => 2167
    [id_shop] => 1
    [date] => 2024-01-01 00:00:00
    [date_modification] => 2024-01-01 00:00:00
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [ishero] => 0
    [prim_key] => 4359
    [id_lang] => 2
    [title] => Up to the maximum-testosterone dose-dependent effects on anabolic and androgen r
    [paragraph] => Up to the maximum-testosterone dose-dependent effects on anabolic and androgen responsive tissues in orchiectomized rats
    [content] => 

Authors
Daniel Derwand, Oliver Zierau, Detlef Thieme, Annekathrin Martina Keiler


Lab

Journal
Andrology

Abstract
The antigen retrieval for the prostate slides was carried out in 10mM Tris-EDTA (pH 9.0) at 60C over night. Then, the Millipore IHC SelectHRP/DAB Kit was used for the nuclear staining with KI67-antibody according to manufacturer's specifications with the following modifications. Endogenous peroxidases were blocked with 3% H2O2for 10min. The blocking was carried out with 20% bovine serum albumin (BSA) in 1xTBS for 1h at room temperature (RT) followed by the primary antibody incubation for 1h RT (rabbit monoclonal Anti-Ki67 antibody [SP6] ab16667, abcam, Lot no. GR3313195, 1:100 in 20% BSA in 1x TBS) in accordance to Chen etal. (2013).22The biotinylated secondary antibody, streptavidin-peroxidase-complex, DAB-solution and hematoxylin solution were provided and used according to the Millipore IHC SelectHRP/DAB Kit. The ready to use secondary-antibody was incubated for 1h RT, the streptavidin-peroxidase complex for 10min, the DAB solution for 4min, and hematoxylin for 10min (followed by 10min bluing in hand warm tap water). As washing buffer were 1xTBS or H2O used according to the kit manual. The stained slides were dehydrated and covered as mentioned before. IgG isotype control was carried out under the same conditions as for the KI-67 Antibody with rabbit IgG-antibody (monoclonal, (EPR25A)-Isotype control, ab172730, abcam, Lot No. 1011223to4, 1:100 in 20% BSA in 1x TBS). For the determination of KI67 positive nuclei, randomly chosen image sections (200x magnification) were completely counted (minimum 200 nuclei per animal). One technical replicate of each animal was evaluated. For the evaluation of the prostate epithelial thickness, three images (200x magnification) from five animals per treatment group were randomly chosen for measurement of epithelial thickness (10 per image).

Keywords/Topics
testosterone;dose-dependent;anabolic;androgen;responsive;tissues;orchiectomized;antigen;retrieval;prostate

BIOSEB Instruments Used:
Bioseb CIS Software (BIO-CIS2),Grip strength test (BIO-GS4),Rodent pincher - Analgesia meter - Wireless (BIO-RP-WRS)

[meta_description] => [meta_keywords] => https://onlinelibrary.wiley.com/doi/abs/10.1111/andr.13466 [meta_title] => [link_rewrite] => Up-to-the-maximum-testosterone-dose-dependent-effects-on-anabolic-and-androgen-responsive-tissues-in-orchiectomized-rats [actif_langue] => 1 [read] => 79 [count_comments] => 0 [id] => 2167 [categories] => Array ( [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) [63] => Array ( [id_prestablog_categorie] => 63 [title] => Système musculaire général [link_rewrite] => Systeme-musculaire-general ) ) [authors] => [paragraph_crop] => Up to the maximum-testosterone dose-dependent effects on anabolic and androgen responsive [...] [link_for_unique] => 1 [products_liaison] => Array ( [1212] => Array ( [name] => Logiciel Bioseb CIS [description_short] =>

Un NOUVEAU logiciel pour augmenter la répétabilité des tests nociceptifs: en enregistrant les réponses réflexes, le logiciel aide l'opérateur à améliorer ses compétences avec l'instrument, ainsi qu'à invalider les résultats hors-limites. Une toute nouvelle fonctionnalité vous autorise désormais également à importer vos données depuis une large gamme de nos instruments pour des analyses supplémentaires sous Excel!

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/fr/douleur-spontanee-deficit-de-posture/1212-bioseb-cis-software.html ) [1218] => Array ( [name] => Algomètre à pince instrumentée pour rongeurs - Sans fil [description_short] =>

Un algomètre rapide et précis, basé sur une pince instrumentée: une alternative au test de Randall-Selitto. Ce nouvel algésimètre développé par Bioseb selon Luis-Delgado et al. (2005) permet des tests nociceptifs précis et la mesure du seuil de douleur mécanique sur pattes de rats ou de souris, avec une contrainte minimale. Maintenant en version sans-fil, pour être libéré des câbles!

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/fr/douleur-allodyniehyperalgesie-mecanique/1218-rodent-pincher-analgesia-meter.html ) [48] => Array ( [name] => Test d'agrippement [description_short] =>

Une méthode simple pour quantifier objectivement la force musculaire des rats et souris et l'effet de drogues, toxines, maladies musculaires (ex: myopathie) et neurodégénératives. Cette mesure de force est souvent employée en association avec le test de coordination motrice ROTAROD: un sujet présentant une coordination normale montrera des résultats médiocres en cas de faible force musculaire. Un must pour vos recherches sur l'activité, la coordination et le contrôle musculaire: particulièrement utile pour vos études sur les maladies de Parkinson et Huntington.

Nouveautés GS4 - 2023: Écran couleur rétroéclairé (meilleure lisibilité), pédale de remise à zéro, durée de batterie optimisée, taille de mémoire augmentée à 500 valeurs, compteur d'animaux, port USB (transfert de données/charge)

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/fr/activite-systeme-moteur-coordination/48-grip-strength-test.html ) ) ) 1
En lire plus

Filtres

Applications

Dates

<< 1 ... 50 51 52 53 54 >>