Arthritis & Osteoarthritis - page 5 Scientific Publications

Latest publication 03/24/2020

Total Knee Arthroplasty with a Ti6Al4V and PEEK Prosthesis on an Osteoarthritis

Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative...

Array
(
    [id_prestablog_news] => 1252
    [id_shop] => 1
    [date] => 2020-03-24 00:00:00
    [date_modification] => 2024-02-09 14:15:12
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [prim_key] => 2461
    [id_lang] => 1
    [title] => Total Knee Arthroplasty with a Ti6Al4V and PEEK Prosthesis on an Osteoarthritis 
    [paragraph] => Total Knee Arthroplasty with a Ti6Al4V/PEEK Prosthesis on an Osteoarthritis Rat Model: Behavioral and Neurophysiological Analysis
    [content] => 

Authors
L Mathieu, L Jean-Marc, J Chaves-Jacob, T Coyle et al


Lab
Aix-Marseille UniversitŽ, CNRS, Institut des Sciences du Mouvement, Marseille, France.

Journal
Scientific Reports

Abstract
Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative functional deficits are reported even after a rehabilitation program. In order to determine the origin of functional deficits of patient suffering from knee osteoarthritis and total knee arthroplasty, we developed a rodent model including a chemically-induced-osteoarthritis and designed a knee prosthesis (Ti6Al4V/PEEK) biomechanically and anatomically adapted to rat knee joint. Dynamic Weight-Bearing, gait kinematics, H-reflex from vastus medialis muscle and activities from metabosensitive III and IV afferent fibers in femoral nerve were assessed at 1 and 3 months post-surgery. Results indicate that knee osteoarthritis altered considerably the responses of afferent fibers to their known activators (i.e., lactic acid and potassium chloride) and consequently their ability to modulate the spinal sensorimotor loop, although, paradoxically, motor deficits seemed relatively light. On the contrary, results indicate that, after the total knee arthroplasty, the afferent responses and the sensorimotor function were slightly altered but that motor deficits were more severe. We conclude that neural changes attested by the recovery of the metabosensitive afferent activity and the sensorimotor loop were induced when a total knee replacement was performed and that these changes may disrupt or delay the locomotor recovery.

BIOSEB Instruments Used
Dynamic Weight Bearing 2.0 (BIO-DWB-DUAL)

[meta_description] => [meta_keywords] => https://search.proquest.com/openview/c3901f2ffbc6bbb8cea8bf10650fa7a1/1?pq-origsite=gscholar&cbl=2041939 [meta_title] => [link_rewrite] => total-knee-arthroplasty-with-a-ti6al4v-and-peek-prosthesis-on-an-osteoarthritis-rat-model--behavioral-and-neurophysiological-analysis [actif_langue] => 1 [read] => 1505 [count_comments] => 0 [id] => 1252 [categories] => Array ( [70] => Array ( [id_prestablog_categorie] => 70 [title] => Arthritis & Osteoarthritis [link_rewrite] => Arthritis-Osteoarthritis ) [21] => Array ( [id_prestablog_categorie] => 21 [title] => Joints [link_rewrite] => Joints ) [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) ) [authors] => [paragraph_crop] => Total Knee Arthroplasty with a Ti6Al4V/PEEK Prosthesis on an Osteoarthritis Rat Model: [...] [link_for_unique] => 1 [products_liaison] => Array ( [1216] => Array ( [name] => Dynamic Weight Bearing 2.0 [description_short] =>

The advanced version of our Dynamic Weight Bearing Test for rodents (rats and mice) allows for faster paw identification, based on a video solution taking advantage of the most advanced algorithms of morphologic analysis, weight distribution and postural changes in dynamic conditions. An efficient and advanced alternative to traditional incapacitance tests (i.e. the paw pressure test or the force plate test) for assessing pain sensitivity in your research on analgesia, hyperalgesia and nociception involving rats and mice, including work on osteoarthritis, bone cancer, analgesic substances, Parkinson disease, allodynia...

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/en/pain-spontaneous-pain-postural-deficit/1216-dynamic-weight-bearing-20.html ) [1877] => Array ( [name] => Dynamic Weight Bearing 2.0 – Postural Module [Add-on] [description_short] =>

Expand Your Analysis with Advanced Postural and Locomotor Calculations

BIOSEB’s renowned Dynamic Weight Bearing (DWB2) system is now more powerful than ever with the addition of the Postural Module. This optional software upgrade extends standard weight-bearing analysis by integrating unique calculations designed to quantify subtle aspects of postural balance, locomotor patterns, and compensatory behaviors.

Developed in collaboration with Dr. Tighilet’s lab from Aix Marseille Université-CNRS, the Postural Module improves your DWB2, providing valuable endpoints for studies on pain, neurology, vestibular dysfunction, and neurodegenerative disorders.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/en/pain-spontaneous-pain-postural-deficit/1877-dynamic-weight-bearing-20-add-on-postural-module.html ) ) ) 1
Read more

Filters

Applications

Dates

<< 1 ... 3 4 5 6 7 >>