Neuropathic pain - page 6 Scientific Publications

Latest publication 05/17/2018

Hydrogen-Rich Saline Activated Autophagy via HIF-1_ Pathways in Neuropathic Pain

Neuropathic pain is a chronic and intractable pain, with very few effective analgesics. It involves an impaired cell autophagy process....

Array
(
    [id_prestablog_news] => 1018
    [id_shop] => 1
    [date] => 2018-05-17 00:00:00
    [date_modification] => 2024-02-09 14:15:12
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [ishero] => 0
    [prim_key] => 1997
    [id_lang] => 1
    [title] => Hydrogen-Rich Saline Activated Autophagy via HIF-1_ Pathways in Neuropathic Pain
    [paragraph] => Hydrogen-Rich Saline Activated Autophagy via HIF-1_ Pathways in Neuropathic Pain Model
    [content] => 

Authors
H Wang, X Huo, H Chen, B Li, J Liu, W Ma, X Wang, K Xie, Y Yu,K Shi


Lab
Pain Management Center, Second Hospital of Tianjin Medical University, and Department of Anesthesiology, Tianjin Medical University General Hospital, Tianjin Research Institute of Anesthesiology Tianjin, China

Journal
BioMed Research International

Abstract
Neuropathic pain is a chronic and intractable pain, with very few effective analgesics. It involves an impaired cell autophagy process. Hydrogen-rich saline (HRS) reportedly reduces allodynia and hyperalgesia in a neuropathic pain model; however, it is unknown whether these effects involve autophagy induction.Methods. We investigated the relationship between HRS and cell autophagy in a neuropathic pain model generated by chronic constriction injury (CCI) in Sprague–Dawley rats. Rats received an intraperitoneal injection of HRS (10_mL/kg daily, from 1 day before until 14 days after CCI), 3MA (autophagy inhibitor), 2ME2 (HIF-1_ inhibitor), or EDHB (HIF-1_ agonist). The mechanical withdrawal threshold (MWT) and thermal withdrawal latency (TWL) were tested 1 day before and 1, 3, 7, 10, and 14 days after the operation. HIF-1_ and cell autophagy markers in the spinal cord were evaluated by western blotting and real-time PCR assays at 14 days after CCI. Autophagosomes with double membranes were identified by transmission electron microscopy. Results. CCI caused behavioral hypersensitivity to mechanical and thermal stimulation in the hind-paw of the injured side. HRS improved MWT and TWL, activated autophagy, and increased autophagosomes and autolysosomes in CCI rats. 3-MA aggravated hyperalgesia and allodynia and suppressed autophagy, while EDHB attenuated hyperalgesia and activated the autophagy procedure and the HIF-1_downstream target gene BNIP3. HIF-1_ inhibitors reversed the regulatory effects of HRS on autophagy in CCI rats at 14 days after spinal cord injury. Conclusion. HRS reduced mechanical hyperalgesia and activation of cell autophagy in neuropathic pain through a HIF1-dependent pathway.

BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)

Keywords/Topics
Neuropathic pain; Pain [meta_description] => [meta_keywords] => https://www.hindawi.com/journals/bmri/2018/4670834/ [meta_title] => [link_rewrite] => hydrogen-rich-saline-activated-autophagy-via-hif-1-pathways-in-neuropathic-pain-model [actif_langue] => 1 [read] => 1522 [count_comments] => 0 [id] => 1018 [categories] => Array ( [29] => Array ( [id_prestablog_categorie] => 29 [title] => Neuropathic pain [link_rewrite] => Neuropathic-pain ) [10] => Array ( [id_prestablog_categorie] => 10 [title] => Pain [link_rewrite] => Pain ) [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) ) [authors] => [paragraph_crop] => Hydrogen-Rich Saline Activated Autophagy via HIF-1_ Pathways in Neuropathic Pain Model [link_for_unique] => 1 [products_liaison] => Array ( [1859] => Array ( [name] => Electronic Von Frey - Wireless [description_short] =>

A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!

This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html ) [1860] => Array ( [name] => Electronic Von Frey 5 with embedded camera [description_short] =>

As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.