Cell therapy for spinal cord injury (SCI) is a promising strategy for clinical application. Both bone marrow mesenchymal stromal cells (MSCs; also...
Array
(
[id_prestablog_news] => 593
[id_shop] => 1
[date] => 2014-03-18 00:00:00
[date_modification] => 2024-02-09 14:15:11
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 1161
[id_lang] => 1
[title] => Bone marrow mesenchymal stromal cells and olfactory ensheathing cells transplant
[paragraph] => Bone marrow mesenchymal stromal cells and olfactory ensheathing cells transplantation after spinal cord injury – a morphological and functional comparison in rats
[content] => Authors
A. Torres-Espín, E. Redondo-Castro, J. Hernández, X. Navarro
Lab
Institute of Neurosciences, Bellaterra, Spain
Journal
European Journal of Neurosciences
Abstract
Cell therapy for spinal cord injury (SCI) is a promising strategy for clinical application. Both bone marrow mesenchymal stromal cells (MSCs; also known as bone marrow-derived ‘mesenchymal stem cells’) and olfactory ensheathing cells (OECs) have demonstrated beneficial effects following transplantation in animal models of SCI. However, due to the large number of affecting parameters that determine the therapy success and the lack of methodological consensus, the comparison of different works is difficult. Therefore, we compared the effects of MSC and OEC transplants at early or delayed time after a spinal cord contusion injury in the rat. Functional outcomes for locomotion, sensory perception and electrophysiological responses were assessed. Moreover, the grafted cells survival and the amount of cavity and spared tissue were studied. The findings indicate that grafted cells survived until 7 days post-injection, but markedly disappeared in the following 2 weeks. Despite the low survival of the cells, MSC and OEC grafts provided tissue protection after early and delayed transplantation. Nevertheless, only acute MSC grafts improved locomotion recovery in treadmill condition and electrophysiological outcomes with respect to the other injured groups. These results, together with previous works, indicate that the MSC seem a better option than OEC for treatment of contusion injuries.
BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
[meta_description] =>
[meta_keywords] => http://onlinelibrary.wiley.com/doi/10.1111/ejn.12542/abstract?deniedAccessCustomisedMessage=&userIsAuthenticated=false
[meta_title] =>
[link_rewrite] => bone-marrow-mesenchymal-stromal-cells-and-olfactory-ensheathing-cells-transplantation-after-spinal-cord-injury--a-morphological-and-functional-comparison-in-rats
[actif_langue] => 1
[read] => 154
[count_comments] => 0
[id] => 593
[categories] => Array
(
[11] => Array
(
[id_prestablog_categorie] => 11
[title] => Central Nervous System (CNS)
[link_rewrite] => Central-Nervous-System-(CNS)
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
[39] => Array
(
[id_prestablog_categorie] => 39
[title] => Spinal Cord
[link_rewrite] => Spinal-Cord
)
)
[authors] =>
[paragraph_crop] => Bone marrow mesenchymal stromal cells and olfactory ensheathing cells transplantation after [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1859] => Array
(
[name] => Electronic Von Frey - Wireless
[description_short] => A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!
This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Electronic Von Frey 5 with embedded camera
[description_short] => As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.
The EVF5 includes an embedded camera inside the stimulator handle and a new, dedicated software revolutionizing the experimental process.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 Read more