We compared the preclinical analgesic activity of three marketed drugs with different pharmacological properties, pregabalin, tramadol and...
Array
(
[id_prestablog_news] => 589
[id_shop] => 1
[date] => 2014-04-12 00:00:00
[date_modification] => 2024-02-09 14:15:11
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 1153
[id_lang] => 1
[title] => Face-to-face comparison of the predictive validity of two models of neuropathic
[paragraph] => Face-to-face comparison of the predictive validity of two models of neuropathic pain in the rat: Analgesic activity of pregabalin, tramadol and duloxetine
[content] => Authors
C. Le Cudennec, V. Castagné
Lab
Porsolt S.A.S., Le Genest Saint Isle, France
Journal
European Journal of Pharmacology
Abstract
We compared the preclinical analgesic activity of three marketed drugs with different pharmacological properties, pregabalin, tramadol and duloxetine, described as effective against neuropathic pain in the clinic. These drugs were tested against evoked pain in two different neuropathic models in the rat, the Bennett (CCI) and the Chung (SNL) models. The selected endpoints were tactile allodynia, tactile hyperalgesia, heat hyperalgesia and cold allodynia. Although all three drugs displayed analgesic activity, the effects observed varied according to the behavioral evaluation. Pregabalin showed clear analgesic effects against cold allodynia and tactile hyperalgesia in both the CCI and Chung models. Tramadol was active against all four endpoints in the Chung model with similar effects in the CCI model, apart from tactile allodynia. Duloxetine inhibited tactile allodynia and heat hyperalgesia in both neuropathic pain models. It also displayed efficacy against tactile hyperalgesia in the CCI model and against cold allodynia in the Chung model. These data confirm that the CCI and the Chung models of neuropathic pain do not detect the activity of analgesics with the same sensitivity. Furthermore, the mode of stimulation (tactile or thermal) and the type of endpoint (allodynia or hyperalgesia) can further influence the observed efficacy of gold standards as well as novel compounds developed for treating neuropathic pain symptoms.
BIOSEB Instruments Used
Cold Hot Plate Test (BIO-CHP),Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)
[meta_description] =>
[meta_keywords] => http://www.sciencedirect.com/science/article/pii/S0014299914002696
[meta_title] =>
[link_rewrite] => face-to-face-comparison-of-the-predictive-validity-of-two-models-of-neuropathic-pain-in-the-rat--analgesic-activity-of-pregabalin--tramadol-and-duloxetine
[actif_langue] => 1
[read] => 1444
[count_comments] => 0
[id] => 589
[categories] => Array
(
[11] => Array
(
[id_prestablog_categorie] => 11
[title] => Central Nervous System (CNS)
[link_rewrite] => Central-Nervous-System-(CNS)
)
[38] => Array
(
[id_prestablog_categorie] => 38
[title] => Nerve regeneration
[link_rewrite] => Nerve-regeneration
)
[29] => Array
(
[id_prestablog_categorie] => 29
[title] => Neuropathic pain
[link_rewrite] => Neuropathic-pain
)
[10] => Array
(
[id_prestablog_categorie] => 10
[title] => Pain
[link_rewrite] => Pain
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Face-to-face comparison of the predictive validity of two models of neuropathic pain in the [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[563] => Array
(
[name] => Cold Hot Plate Test
[description_short] => For testing animal's thermal sensitivity to pain resulting from exposure to heat or cold: the Cold Hot Plate is an innovative instrument opening new investigation fields for your analgesia and nociception research, and a useful tool for analgesic drug screening using rats or mice models.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/en/pain-thermal-allodynia-hyperalgesia/563-cold-hot-plate-test.html
)
[1859] => Array
(
[name] => Electronic Von Frey - Wireless
[description_short] => A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!
This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html
)
[1860] => Array
(
[name] => Electronic Von Frey 5 with embedded camera
[description_short] => As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.
The EVF5 includes an embedded camera inside the stimulator handle and a new, dedicated software revolutionizing the experimental process.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1860-electronic-von-frey-5-with-embedded-camera.html
)
)
)
1 Read more