Publications

Latest publication 04/05/2016

Effect of dexmedetomidine and cold stress in a rat model of neuropathic pain- Ro

Dexmedetomidine (Dex) is a novel Alpha 2-adrenoceptor agonist. It decreases sympathetic tone and attenuates the stress responses to anesthesia and...

Array
(
    [id_prestablog_news] => 828
    [id_shop] => 1
    [date] => 2016-04-05 00:00:00
    [date_modification] => 2024-02-09 14:15:12
    [langues] => ["1","2"]
    [actif] => 1
    [slide] => 0
    [url_redirect] => 
    [average_rating] => 
    [number_rating] => 
    [author_id] => 1
    [featured] => 0
    [prim_key] => 1619
    [id_lang] => 1
    [title] => Effect of dexmedetomidine and cold stress in a rat model of neuropathic pain- Ro
    [paragraph] => Effect of dexmedetomidine and cold stress in a rat model of neuropathic pain: Role of interleukin-6 and tumor necrosis factor-α
    [content] => 

Authors
Farghaly HS, Mahmoud AM, Abdel-Sater KA


Lab
Department of Pharmacology, Faculty of Medicine, Assiut University, Assiut, Egypt.

Journal
Eur J Pharmacol.

Abstract
Dexmedetomidine (Dex) is a novel Alpha 2-adrenoceptor agonist. It decreases sympathetic tone and attenuates the stress responses to anesthesia and surgery. People exposed to cold suffer unpleasant thermal pain, which is experienced as stress and causes the release of noradrenaline from the sympathetic terminals. The present study investigated the effects of cold stress and dexmedetomidine on chronic constriction injury (CCI) model of the sciatic nerve in rats. Sixty four male Wistar rats were divided into seven groups of eight rats each: repeated cold stress (RCS) group, sham RCS group, CCI group, sham CCI group, Dex-treated group received a single dose of Dex (5μg/kg), CCI+Dex group, CCI+RCS group. Interleukin-6 (IL-6) and tumor necrosis factor- alpha (TNF-α) levels in the serum were measured by enzyme-linked immunosorbent assay. The mean body weight of CCI, RCS, CCI+RCS, CCI+Dex and RCS+Dex groups decreased significantly compared with pre-values. Dexmedetomidine and CCI caused significant changes of the systolic, diastolic and mean blood pressure. Both RCS and CCI groups showed significant decreased of reaction time in the hot plate test. The RCS and CCI groups demonstrated a significant mechanical hyperalgesia, while pain threshold was increased in the RCS+Dex group. A significant decrease of serum IL-6 and TNF-α was demonstrated in CCI+RCS and CCI+Dex groups. The therapeutic effectiveness of dexmedetomidine in neuropathic pain may be through inhibition of proinflammatory cytokines, primarily IL-6 and TNF-α. Moreover, cold stress may result in increased resistance to neuropathic pain.

BIOSEB Instruments Used
Electronic Von Frey 4 (BIO-EVF4),Electronic Von Frey 5 with embedded camera (BIO-EVF5)

[meta_description] => [meta_keywords] => http://www.ncbi.nlm.nih.gov/pubmed/26896779 [meta_title] => [link_rewrite] => effect-of-dexmedetomidine-and-cold-stress-in-a-rat-model-of-neuropathic-pain--role-of-interleukin-6-and-tumor-necrosis-factor- [actif_langue] => 1 [read] => 1156 [count_comments] => 0 [id] => 828 [categories] => Array ( [26] => Array ( [id_prestablog_categorie] => 26 [title] => Miscellaneous research domains [link_rewrite] => Miscellaneous-research-domains ) [2] => Array ( [id_prestablog_categorie] => 2 [title] => Publications [link_rewrite] => publications ) ) [authors] => [paragraph_crop] => Effect of dexmedetomidine and cold stress in a rat model of neuropathic pain: Role of [...] [link_for_unique] => 1 [products_liaison] => Array ( [1859] => Array ( [name] => Electronic Von Frey - Wireless [description_short] =>

A quick solution to determine the mechanical sensitivity threshold in rodents (mice and rats). Now wireless, to be free from annoying cables!

This precise and easy-to-use electronic instrument is a must-have reference for your research in analgesia, nociception, neuro-pathologies and post-operative pain.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1859-electronic-von-frey-4.html ) [1860] => Array ( [name] => Electronic Von Frey 5 with embedded camera [description_short] =>

As an electronic version of the classical Von Frey Filaments esthesiometer (or aesthesiometer), the latest evolution of Bioseb's Electronic Von Frey instrument for determining the mechanical sensitivity threshold in rodents (rats and mice) is a must-have instrument for your reseach on hyperalgesia and allodynia. By measuring and recording the force at which the animal exhibits a paw withdrawal reflex, pathologies related to sensory response and hyper- or hypo-aesthesia can be studied.

The EVF5 includes an embedded camera inside the stimulator handle and a new, dedicated software revolutionizing the experimental process.

Instrument for ratsInstrument for mice

[thumb] => [img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg [image_presente] => 1 [link] => https://bioseb.com/en/pain-mechanical-allodynia-hyperalgesia/1860-electronic-von-frey-5-with-embedded-camera.html ) ) ) 1